Home / Docs Center / Device API Reference / ModifyConfigurationParameters

ModifyConfigurationParameters

Device API Reference · New API

Project: Device API Documentation (New Version) | page_id: 277

Brief Description:

  • Modify configuration parameters

Request URL:
- /xsw/modValues

Request Method:
- POST

Parameters:

Parameter Required Type Description
key1 Yes string The key in config
value1 Yes string The value corresponding to the key
type1 No string number float bool string, string by default

Response Example

  {"code":0,"msg":""}

Response Parameter Description

Parameter Type Description
code int 0 success, others failure
msg string Error message

Description of Some Parameters

Parameter key type value
Manual Exposure encode.0.vi_param.0.manualExposure number 0 disabled, 1 enabled
Exposure Time encode.0.vi_param.0.exposure number 0-5391
Full Color Mode encode.0.vi_param.0.whiteLightEnable number 0 disabled, 1 enabled
Fill Light Control encode.0.vi_param.0.lightControlMode number 0 off, 1 infrared fill light, 2 white light, 3 auto
Highlight Suppression Strength encode.0.vi_param.0.lightDepress number 0-255
Backlight Compensation Strength encode.0.vi_param.0.aeBLCStrength number 0-10
Brightness encode.0.vi_param.0.brightness number 0-255
Contrast encode.0.vi_param.0.contrast number 0-255
Saturation encode.0.vi_param.0.saturation number 0-255
Sharpness encode.0.vi_param.0.sharpness number 0-255
Max Analog Gain encode.0.vi_param.0.maxAgain number 0-400
Max Digital Gain encode.0.vi_param.0.maxDgain number 0-256

Examples:
- Enable full color mode
http://192.168.0.30/xsw/modValues?key1=encode.0.vi_param.0.whiteLightEnable&value1=1&type1=number&t=1755583204&token=xxxxx
- Enable exposure and set the exposure time to 5000
http://192.168.0.30/xsw/modValues?key1=encode.0.vi_param.0.manualExposure&value1=1&type1=number&key2=encode.0.vi_param.0.exposure&value2=5000&type2=number&t=1755583204&token=xxxxx

Notes

  • Modification restarts the streaming.
  • A maximum of 10 parameters can be modified at the same time.